ACTUATOR FUNCTION | TRIP-RESETTRIP-RESET |
ACTUATOR POSITION DESIGNATION | AT POLE ONEAT POLE ONE |
ARC QUENCHING METHOD | AIRAIR |
AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 CONTROL1 CONTROL |
BODY LENGTH | 2.500 INCHES NOMINAL2.500 INCHES NOMINAL |
BODY STYLE | SINGLE POLE TYPESINGLE POLE TYPE |
BODY WIDTH | 0.750 INCHES NOMINAL0.750 INCHES NOMINAL |
BOSS HEIGHT | 0.140 INCHES NOMINAL0.140 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.938 INCHES NOMINAL1.938 INCHES NOMINAL |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATIONOVERCURRENT SINGLE LOCATION |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.062 INCHES NOMINAL2.062 INCHES NOMINAL |
FRAGILITY FACTOR | MODERATELY RUGGEDMODERATELY RUGGED |
FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION400.0 SINGLE LOCATION |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | MOISTURE RESISTANTMOISTURE RESISTANT |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATIONSERIES TRIP SINGLE LOCATION |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREETRIP FREE |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE1 TOGGLE |
MATERIAL | PLASTIC CASEPLASTIC CASE |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 250.0 MILLIAMPERES AC SINGLE LOCATION250.0 MILLIAMPERES AC SINGLE LOCATION |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SINGLE LOCATION1000.0 AC SINGLE LOCATION |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE(S)2 THREADED HOLE(S) |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.611 INCHES NOMINAL2.611 INCHES NOMINAL |
NOMINAL THREAD SIZE | 0.138 INCHES0.138 INCHES |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SINGLE LOCATION250.0 AC SINGLE LOCATION |
POLE QUANTITY | 11 |
RESET METHOD | MANUALMANUAL |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE |
SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONEINTERNAL AT POLE ONE |
SWITCH TERMINAL TYPE | TAB, SOLDER LUGTAB, SOLDER LUG |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 250.0 AC AND 50.0 DC50.0 DC |
SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROWSINGLE POLE, DOUBLE THROW |
SWITCH CURRENT RATING AND TYPE IN AMPS | 2.5 AC AND 2.5 AC AND 1.0 DC1.0 DC |
TERMINAL TYPE AND QUANTITY | 2 THREADED STUD2 THREADED STUD |
THREAD QUANTITY PER INCH | 3232 |
THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC)UNIFIED NATIONAL COARSE (UNC) |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATIONTIME DELAY SINGLE LOCATION |
TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATIONMAGNETIC-HYDRAULIC SINGLE LOCATION |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.100 MINIMUM AT 200 PCT AND 2.100 MINIMUM AT 200 PCT AND 7.000 MAXIMUM AT 200 PCT SINGLE LOCATION7.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 SINGLE LOCATION150.0 SINGLE LOCATION |
ULTIMATE TRIP TIME PER POLE IN SECONDS | 7.000 MINIMUM AND 7.000 MINIMUM AND 40.000 MAXIMUM SINGLE LOCATION40.000 MAXIMUM SINGLE LOCATION |