| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC AND 32.0 DC SINGLE LOCATION |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 SINGLE LOCATION |
| RESET METHOD | MANUAL |
| BODY WIDTH | 0.750 INCHES NOMINAL |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.188 INCHES NOMINAL |
| TERMINAL TYPE AND QUANTITY | 2 SCREW |
| TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
| THREAD SERIES DESIGNATOR | UNC |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CASE MATERIAL | PLASTIC |
| TRIP RELEASE METHOD | THERMAL-MAGNETIC SINGLE LOCATION |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 18.000 MINIMUM AT 200 PCT AND 70.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC AND 50.0 AMPERES DC SINGLE LOCATION |
| ACTUATOR FUNCTION | TRIP-RESET |
| NOMINAL THREAD SIZE | 0.138 INCHES |
| BODY LENGTH | 2.189 INCHES NOMINAL |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.000 INCHES NOMINAL |
| FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
| POLE QUANTITY | 1 |
| MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| THREAD QUANTITY PER INCH | 32 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3000.0 AC AND 3000.0 DC SINGLE LOCATION |
| BODY STYLE | SINGLE POLE TYPE |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
| BUSHING LENGTH | 0.156 INCHES NOMINAL |
| ACTUATOR POSITION DESIGNATION | AT POLE ONE |