| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 CONTROL |
| BODY LENGTH | 1.735 INCHES MINIMUM AND 1.765 INCHES MAXIMUM |
| BODY STYLE | SINGLE POLE TYPE |
| BODY WIDTH | 0.615 INCHES MINIMUM AND 0.635 INCHES MAXIMUM |
| BUSHING LENGTH | 0.280 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.225 INCHES MINIMUM AND 1.255 INCHES MAXIMUM |
| CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
| MATERIAL | ALUMINUM CASE |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 25.0 AMPERES DC SINGLE LOCATION |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2500.0 DC SINGLE LOCATION |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.623 INCHES MINIMUM AND 1.653 INCHES MAXIMUM |
| NOMINAL THREAD SIZE | 0.469 INCHES |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 32.0 DC SINGLE LOCATION |
| POLE QUANTITY | 1 |
| RESET METHOD | MANUAL |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.110 INCHES MINIMUM AND 0.140 INCHES MAXIMUM |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| SWITCH TERMINAL TYPE | TURRET |
| SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 28.0 DC |
| SWITCH CONTACT ARRANGEMENT | SINGLE POLE, SINGLE THROW, NORMALLY OPEN |
| SWITCH CURRENT RATING AND TYPE IN AMPS | 7.0 DC |
| SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
| TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |
| THREAD QUANTITY PER INCH | 32 |
| THREAD SERIES DESIGNATOR | UNS |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.700 MINIMUM AT 200 PCT AND 4.500 MAXIMUM AT 200 PCT SINGLE LOCATION |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATION |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 SINGLE LOCATION |
| ULTIMATE TRIP TIME PER POLE IN SECONDS | 12.000 MAXIMUM SINGLE LOCATION |