| BODY LENGTH | 0.248 INCHES MINIMUM AND 0.252 INCHES MAXIMUM |
| BODY STYLE | PLUG-IN TYPE |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO DIAMETER | 0.142 INCHES MINIMUM AND 0.152 INCHES MAXIMUM |
| CIRCUIT OVER-CURRENT INTERRUPTION TYPE | NORMAL INSTANTANEOUS |
| CONTINUOUS CURRENT RATING IN AMPS | 5.000 |
| FEATURES PROVIDED | NONRENEWABLE FUSIBLE ELEMENT |
| INTERRUPTION INDICATOR METHOD | OPAQUE BODY |
| OVERALL LENGTH | 0.416 INCHES MINIMUM AND 0.424 INCHES MAXIMUM |
| MATERIAL | CERAMIC CASE |
| MAXIMUM VOLTAGE RATING IN VOLTS | 125.0 AC AND 125.0 DC |
| OVERALL DIAMETER | 0.268 INCHES MINIMUM AND 0.272 INCHES MAXIMUM |
| SPECIFICATION/STANDARD DATA | 81349-MIL-F-23419/1 GOVERNMENT SPECIFICATION |
| SURFACE TREATMENT | NICKEL TERMINAL |
| TERMINAL LENGTH | 0.168 INCHES MINIMUM AND 0.172 INCHES MAXIMUM |
| TERMINAL DIAMETER | 0.039 INCHES MINIMUM AND 0.043 INCHES MAXIMUM |
| TEST DATA DOCUMENT | 81349-MIL-F-23419 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |