| BODY MATERIAL | ALUMINUM |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.500 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.500 INCHES NOMINAL |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 37 FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT LOCATION NOT OTHERWISE SPECIFIED |
| FEATURES PROVIDED | CORROSION RESISTANT |
| FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 10.0 AND 100.0 |
| FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | 8.0 AND 44.0 |
| INCLOSURE TYPE | ENCASED |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| OVERALL HEIGHT | 2.338 INCHES NOMINAL |
| OVERALL LENGTH | 1.802 INCHES MINIMUM AND 1.823 INCHES MAXIMUM |
| OVERALL WIDTH | 1.802 INCHES MINIMUM AND 1.823 INCHES MAXIMUM |
| MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 800.0 VOLTS AT ALTITUDE |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT LOCATION NOT OTHERWISE SPECIFIED |
| MOUNTING SLOT WIDTH | 0.148 INCHES MINIMUM AND 0.164 INCHES MAXIMUM |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 13.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 13.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 13.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 13.0 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 13.0 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 13.0 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE AND 320.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE AND 320.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE AND 320.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OPERATING TEMP RANGE | -55.0 TO 125.0 CELSIUS |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 4TH RADIO INTERFERENCE AND 320.0 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 6TH RADIO INTERFERENCE AND 320.0 VOLTS DC 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 5TH RADIO INTERFERENCE AND 320.0 VOLTS DC 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| SPECIAL FEATURES | 37 FILTERED FUNCTIONS |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES GOLD |
| PRECIOUS MATERIAL | GOLD |
| STYLE DESIGNATOR | FILTER CONNECTOR |