5930-01-392-9181 SWITCH,PUSH Index 5935-01-392-9183 CONNECTOR,RECEPTACLE,ELECTRICAL

National Stock Number:
5915-01-392-9182

Federal Supply Class:
5915

National Item Identification Number:
013929182

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
6300183-113B150RAYTHEON COMPANY
6300183-1149956RAYTHEON COMPANY
9903-153B0LSP2SPECTRUM CONTROL, INC.
6300183-1154X10RAYTHEON COMPANY
ZR2CK-153HA59942AVX FILTERS CORPORATION
6300183-1182577RAYTHEON COMPANY


Techincal Specification:
BODY LENGTH0.195 INCHES MINIMUM AND 0.205 INCHES MAXIMUM
BODY OUTSIDE DIAMETER0.151 INCHES MINIMUM AND 0.161 INCHES MAXIMUM
BODY MATERIALMETAL
BODY SURFACE TREATMENTGOLD
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 WIRE LEAD INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 WIRE LEAD OUTPUT SECOND FUNCTION
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS7.0 AND 25.0 AND 45.0 AND 60.0
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ1.0 AND 10.0 AND 100.0 AND 1000.0
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH1.400 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE50.0 VOLTS AT SEA LEVEL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRECIOUS MATERIAL AND LOCATIONCASE AND TERMINAL SURFACES GOLD
PRECIOUS MATERIALGOLD
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCAPACITANCE-INDUCTANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES