5935-01-388-6523 COVER,ELECTRICAL CONNECTOR Index 5910-01-388-6525 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5915-01-388-6524

Federal Supply Class:
5915

National Item Identification Number:
013886524

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
2001090-00466948L3HARRIS TECHNOLOGIES, INC.
B70A-SER06351MICROWAVE ENGINEERING CORPORATION


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION0.6 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY MATERIALMETAL
BODY LENGTH7.071 INCHES NOMINAL
BODY WIDTH6.000 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 NOMINAL BLANK AND 10.0 NOMINAL BLANK LOCATION NOT OTHERWISE SPECIFIED
FEATURES PROVIDEDFUNGUS RESISTANT AND SHOCK RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION10.00 GIGAHERTZ BLANK AND 10.30 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, PLUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, PLUG OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.3 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH9.000 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 FLANGE LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT6.000 INCHES MAXIMUM
REFERENCE FREQUENCY PER FUNCTION10.15 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION20.00 GIGAHERTZ BLANK AND 30.00 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.2 BLANK LOCATION NOT OTHERWISE SPECIFIED