5935-01-377-5815 CONNECTOR,RECEPTACLE,ELECTRICAL Index 6350-01-377-5818 ALARM,AUDIBLE-VISUAL

National Stock Number:
5915-01-377-5816

Federal Supply Class:
5915

National Item Identification Number:
013775816

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
M15733/72-006781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-F-15733/7281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-15733/7281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY LENGTH4.690 INCHES MINIMUM AND 4.810 INCHES MAXIMUM
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER2.270 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 THREADED STUD OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 THREADED STUD INPUT FIRST FUNCTION
FEATURES PROVIDEDSHOCK RESISTANT AND MOISTURE RESISTANT
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.014 AND 0.02 AND 0.05 AND 0.15 AND 0.3 AND 0.6 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS15.0 AND 18.0 AND 28.0 AND 37.0 AND 45.0 AND 53.0 AND 58.0 AND 70.0
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION30.0 VOLTS AC BLANK AND 30.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH6.910 INCHES NOMINAL
MAXIMUM TEMP RISE35.0 CELSIUS
MAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC BLANK AND 1.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNEF
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE1.125 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFICATION/STANDARD DATA81349-MIL-F-15733/72 GOVERNMENT SPECIFICATION
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
TEST DATA DOCUMENT81349-MIL-F-15733 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).