5950-01-377-0846 COIL,RADIO FREQUENCY Index 5935-01-377-0848 CONNECTOR,RECEPTACLE,ELECTRICAL

National Stock Number:
5915-01-377-0847

Federal Supply Class:
5915

National Item Identification Number:
013770847

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
10109860-10194580HONEYWELL INTERNATIONAL INC.
5IB40-100/5-P/P50140K&L MICROWAVE LLC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION0.1 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY HEIGHT0.400 INCHES NOMINAL
BODY LENGTH1.000 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH0.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 50.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
FREQUENCY BAND WIDTH PER FUNCTION97.50 MEGAHERTZ BLANK AND 102.50 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 PIN GROUND THIRD FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY TYPE AND QUANTITY6 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-20.0 TO 85.0 CELSIUS
OVERALL HEIGHT0.520 INCHES NOMINAL
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION100.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: OZ3.000
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION90.00 MEGAHERTZ BLANK AND 97.50 MEGAHERTZ BLANK AND 102.50 MEGAHERTZ BLANK AND 110.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION97.5 MEGAHERTZ BLANK AND 102.5 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED


Click here to Register for Free 30-day Trial