5915-01-376-2993 FILTER,BAND PASS Index 5307-01-376-2995 STUD,PLAIN

National Stock Number:
5915-01-376-2994

Federal Supply Class:
5915

National Item Identification Number:
013762994

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
M15733/73-006381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-F-1573381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-15733/7381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY LENGTH4.940 INCHES MINIMUM AND 5.060 INCHES MAXIMUM
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER1.770 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 THREADED STUD OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 THREADED STUD INPUT FIRST FUNCTION
FEATURES PROVIDEDSHOCK RESISTANT AND MOISTURE RESISTANT
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.014 AND 0.02 AND 0.05 AND 0.15 AND 0.3 AND 0.6 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS15.0 AND 18.0 AND 28.0 AND 37.0 AND 45.0 AND 53.0 AND 58.0 AND 70.0
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC BLANK AND 400.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH6.865 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE1000.0 VOLTS AT SEA LEVEL
MAXIMUM TEMP RISE25.0 CELSIUS
MAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC BLANK AND 1.15 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.750 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFICATION/STANDARD DATA81349-MIL-F-15733/73 GOVERNMENT SPECIFICATION
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
TEST DATA DOCUMENT81349-MIL-F-15733 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).


Click here to Register for Free 30-day Trial