5915-01-376-1478 FILTER,BAND PASS Index 5915-01-376-1480 FILTER,BAND PASS

National Stock Number:
5915-01-376-1479

Federal Supply Class:
5915

National Item Identification Number:
013761479

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
8901106312339DRS TRAINING & CONTROL SYSTEMS, LLC
BPF-L-770-100-1282156216TELEDYNE WIRELESS, LLC
S6B-77.410C-CPP/10K0R2ANATECH ELECTRONICS INC
MC77.4-X10-6MM56216TELEDYNE WIRELESS, LLC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION0.1 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY HEIGHT0.380 INCHES MINIMUM AND 0.420 INCHES MAXIMUM
BODY LENGTH1.730 INCHES MINIMUM AND 1.770 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH0.530 INCHES MINIMUM AND 0.570 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS50.0 NOMINAL BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FEATURES PROVIDEDSHOCK RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION72.40 MEGAHERTZ BLANK AND 82.40 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OVERALL HEIGHT0.550 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION77.4 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION100.00 MEGAHERTZ BLANK AND 300.00 MEGAHERTZ BLANK AND 1.00 HERTZ BLANK AND 50.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial