5365-01-361-9134 SPACER,SLEEVE Index 5915-01-361-9136 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-361-9135

Federal Supply Class:
5915

National Item Identification Number:
013619135

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
695025120PIEZO TECHNOLOGY INCORPORATED
758-00158997VECTRON INTERNATIONAL, INC.
FA-296654832AEROFLEX LABORATORIES INC COMSTRON DIV
A3060786-00180063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY HEIGHT0.485 INCHES MINIMUM AND 0.515 INCHES MAXIMUM
BODY LENGTH1.485 INCHES MINIMUM AND 1.515 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH0.985 INCHES MINIMUM AND 1.015 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 40.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN GROUND THIRD FUNCTION
FEATURES PROVIDEDMOISTURE RESISTANT AND SHOCK RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION69.97 MEGAHERTZ BLANK AND 70.03 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT0.875 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-35.0 TO 85.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION70.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 200.0
VOLTAGE STANDING WAVE RATIO PER FUNCTION2.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION69.97 MEGAHERTZ BLANK AND 70.03 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION69.94 MEGAHERTZ BLANK AND 69.97 MEGAHERTZ BLANK AND 70.03 MEGAHERTZ BLANK AND 70.06 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial