5915-01-357-9467 FILTER,RADIO FREQUENCY INTERFERE Index 5930-01-357-9469 SWITCH,THERMOSTATIC

National Stock Number:
5915-01-357-9468

Federal Supply Class:
5915

National Item Identification Number:
013579468

Description:
FILTER,HIGH PASS

Detail:
AN ITEM DESIGNED TO PASS ALL FREQUENCIES ABOVE A SPECIFIED FREQUENCY. EXCLUDES A SINGLE INDUCTANCE, A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); REACTOR; CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).


Manufacturer Information:
302757-00165628CAES SYSTEMS LLC
330596-10181413BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
6432764639CARLISLE INTERCONNECT TECHNOLOGIES INC
UT-6432764639CARLISLE INTERCONNECT TECHNOLOGIES INC
330596-20181413BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.


Techincal Specification:
AVERAGE LIFE RATING IN HOURS200000.0
BODY MATERIALMETAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 60.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.00 GIGAHERTZ BLANK AND 5.00 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.75 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH3.675 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-40.0 TO 95.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION5.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESELECTROSTATIC DISCHARGE SENSITIVE
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.00 GIGAHERTZ BLANK AND 5.00 GIGAHERTZ BLANK AND 10.00 GIGAHERTZ BLANK AND 15.00 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+50.0 TO 1000.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION1.0 GIGAHERTZ BLANK AND 5.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.3 BLANK LOCATION NOT OTHERWISE SPECIFIED


Click here to Register for Free 30-day Trial