5915-01-354-6108 FILTER,RADIO FREQUENCY INTERFERE Index 7310-01-354-6110 RANGE,GAS

National Stock Number:
5915-01-354-6109

Federal Supply Class:
5915

National Item Identification Number:
013546109

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
LA 120N00929MICROLAB/FXR LLC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION50.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER0.375 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.0 MINIMUM BLANK AND 55.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, PLUG OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION4.80 GIGAHERTZ BLANK AND 12.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
INPUT TERMINAL MANUFACTURER CODE00929
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.2 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 150.0 CELSIUS
OUTPUT TERMINAL IDENTIFICATIONSMA-PLUG
OUTPUT TERMINAL MANUFACTURER CODE00929
OVERALL LENGTH2.500 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRECIOUS MATERIAL AND LOCATIONBODY SURFACES SILVER
PRECIOUS MATERIALSILVER
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION12.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
UNPACKAGED UNIT WEIGHT3.000 OUNCES NOMINAL
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION4.8 GIGAHERTZ BLANK AND 12.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.7 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION4.80 GIGAHERTZ BLANK AND 12.00 GIGAHERTZ BLANK AND 14.40 GIGAHERTZ BLANK AND 18.00 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES