| AVERAGE LIFE RATING IN HOURS | 200000.0 |
| BODY MATERIAL | ALUMINUM |
| BODY SURFACE TREATMENT | TIN |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.290 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.600 INCHES NOMINAL |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD INPUT FIRST FUNCTION |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.5 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.5 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.5 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OPERATING TEMP RANGE | -55.0 TO 85.0 CELSIUS |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| MAXIMUM TEMP RISE | 45.0 CELSIUS |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| NUCLEAR HARDNESS CRITICAL FEATURE | HARDENED |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION |
| SPECIAL FEATURES | NUCLEAR HARDNESS CRITICAL ITEMS |
| UNPACKAGED UNIT WEIGHT | 1.500 POUNDS NOMINAL |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.235 INCHES NOMINAL |
| VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 2000.0 |