4810-01-349-8963 VALVE,SOLENOID Index 5930-01-349-8965 SWITCH,PRESSURE

National Stock Number:
5915-01-349-8964

Federal Supply Class:
5915

National Item Identification Number:
013498964

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
3255215-210001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
6L380-0000150140K&L MICROWAVE LLC
LA-M7600929MICROLAB/FXR LLC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION50.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER0.485 INCHES MINIMUM AND 0.515 INCHES MAXIMUM
BODY SURFACE TREATMENTSILVER
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 52.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, PLUG OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.60 GIGAHERTZ BLANK AND 3.60 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
INPUT TERMINAL MANUFACTURER CODE00929
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.3 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATIONSMA-PLUG
OUTPUT TERMINAL MANUFACTURER CODE00929
OVERALL LENGTH3.650 INCHES MINIMUM AND 3.770 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-28.0 TO 75.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRECIOUS MATERIAL AND LOCATIONBODY SURFACES SILVER
PRECIOUS MATERIALSILVER
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION3.64 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.60 GIGAHERTZ BLANK AND 3.60 GIGAHERTZ BLANK AND 4.20 GIGAHERTZ BLANK AND 5.40 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION1.6 GIGAHERTZ BLANK AND 3.6 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.3 BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNPACKAGED UNIT WEIGHT4.000 OUNCES NOMINAL


Click here to Register for Free 30-day Trial