4820-01-340-9962 VALVE,BALL Index 5915-01-340-9964 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-340-9963

Federal Supply Class:
5915

National Item Identification Number:
013409963

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
F-35610AM43LCR ELECTRONICS, INC


Techincal Specification:
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 THREADED STUD INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 THREADED STUD OUTPUT SECOND FUNCTION
FEATURES PROVIDEDNUT AND WASHER
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 2ND RADIO INTERFERENCE AND 600.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 1ST RADIO INTERFERENCE AND 600.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 3RD RADIO INTERFERENCE AND 600.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE500.0 VOLTS AT SEA LEVEL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE1.2 KILOVOLTS AT SEA LEVEL
MAXIMUM TEMP RISE40.0 CELSIUS
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 2ND RADIO INTERFERENCE AND 6.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 3RD RADIO INTERFERENCE AND 6.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 1ST RADIO INTERFERENCE AND 6.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE THIRD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
SPECIAL FEATURESTHREE FILTERED FUNCTIONS


Click here to Register for Free 30-day Trial