4820-01-339-7280 VALVE,SAFETY RELIEF Index 5307-01-339-7282 STUD,CONTINUOUS THREAD

National Stock Number:
5915-01-339-7281

Federal Supply Class:
5915

National Item Identification Number:
013397281

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
049-000491-00126916NORTHROP GRUMMAN SYSTEMS CORPORATION
F550020AM43LCR ELECTRONICS, INC


Techincal Specification:
OPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 1ST RADIO INTERFERENCE 1ST FUNCTION
30.0 2ND RADIO INTERFERENCE 2ND FUNCTION
30.0 3RD RADIO INTERFERENCE 3RD FUNCTION
30.0 4TH RADIO INTERFERENCE 4TH FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 THREADED STUD INPUT 1ST FUNCTION
4 THREADED STUD OUTPUT 2ND FUNCTION
2 THREADED STUD GROUND 3RD FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY8 THREADED STUD
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
250.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
250.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
250.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE 1ST FUNCTION
60.0 2ND RADIO INTERFERENCE 2ND FUNCTION
60.0 3RD RADIO INTERFERENCE 3RD FUNCTION
60.0 4TH RADIO INTERFERENCE 4TH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
2.5 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
2.5 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
2.5 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
OVERALL LENGTH7.700 INCHES NOMINAL
BODY LENGTH6.500 INCHES NOMINAL
BODY HEIGHT2.250 INCHES NOMINAL
BODY WIDTH5.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.620 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.500 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.164 INCHES
FEATURES PROVIDEDNUT AND
WASHER
SPECIAL FEATURESFOUR FILTERED FUNCTIONS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
MAXIMUM TEMP RISE25.0 DEG CELSIUS
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.0 AND
0.15 AND
2.0 AND
5.0 AND
10.0 AND
20.0
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS15.0 AND
20.0 AND
40.0 AND
50.0
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE2.25 KILOVOLTS AT SEA LEVEL
OPERATING TEMP RANGE-55.0 TO 125.0 DEG CELSIUS
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN


Click here to Register for Free 30-day Trial