4820-01-339-4138 VALVE,VENT Index 5915-01-339-4140 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-339-4139

Federal Supply Class:
5915

National Item Identification Number:
013394139

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
142307-000106481NORTHROP GRUMMAN SYSTEMS CORPORATION
BPF-L-070-100-1045656216TELEDYNE WIRELESS, LLC


Techincal Specification:
BODY HEIGHT0.250 INCHES NOMINAL
BODY LENGTH0.760 INCHES NOMINAL
BODY MATERIALALUMINUM
BODY SURFACE TREATMENTNICKEL
BODY WIDTH0.460 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.0 MINIMUM 4TH BAND PASS AND 60.0 MAXIMUM 4TH BAND PASS FOURTH FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.0 MINIMUM 1ST BAND PASS AND 60.0 MAXIMUM 1ST BAND PASS FIRST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.0 MINIMUM 2ND BAND PASS AND 60.0 MAXIMUM 2ND BAND PASS SECOND FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.0 MINIMUM 3RD BAND PASS AND 60.0 MAXIMUM 3RD BAND PASS THIRD FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.300 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 PIN OUTPUT SECOND FUNCTION
FEATURES PROVIDEDMOISTURE RESISTANT AND SHOCK RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION68.00 MEGAHERTZ 3RD BAND PASS AND 72.00 MEGAHERTZ 3RD BAND PASS THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION68.00 MEGAHERTZ 4TH BAND PASS AND 72.00 MEGAHERTZ 4TH BAND PASS FOURTH FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION68.00 MEGAHERTZ 1ST BAND PASS AND 72.00 MEGAHERTZ 1ST BAND PASS FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION68.00 MEGAHERTZ 2ND BAND PASS AND 72.00 MEGAHERTZ 2ND BAND PASS SECOND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS4.0 2ND BAND PASS SECOND FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS4.0 3RD BAND PASS THIRD FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS4.0 4TH BAND PASS FOURTH FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS4.0 1ST BAND PASS FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST BAND PASS FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD BAND PASS THIRD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND BAND PASS SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH BAND PASS FOURTH FUNCTION
OVERALL HEIGHT0.430 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY16 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND BAND PASS SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST BAND PASS FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH BAND PASS FOURTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD BAND PASS THIRD FUNCTION
PRECIOUS MATERIAL AND LOCATIONCONTACT SURFACES GOLD
PRECIOUS MATERIALGOLD
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST BAND PASS FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND BAND PASS SECOND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH BAND PASS FOURTH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD BAND PASS THIRD FUNCTION
REFERENCE FREQUENCY PER FUNCTION70.0 MEGAHERTZ 1ST BAND PASS FIRST FUNCTION
REFERENCE FREQUENCY PER FUNCTION70.0 MEGAHERTZ 2ND BAND PASS SECOND FUNCTION
REFERENCE FREQUENCY PER FUNCTION70.0 MEGAHERTZ 3RD BAND PASS THIRD FUNCTION
REFERENCE FREQUENCY PER FUNCTION70.0 MEGAHERTZ 4TH BAND PASS FOURTH FUNCTION
SPECIAL FEATURESFOUR FILTERED FUNCTIONS,FOUR UNFILTERED FUNCTION
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 500.0
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 1ST BAND PASS FIRST FUNCTION
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 2ND BAND PASS SECOND FUNCTION
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 3RD BAND PASS THIRD FUNCTION
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 4TH BAND PASS FOURTH FUNCTION
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION68.0 MEGAHERTZ 1ST BAND PASS AND 72.0 MEGAHERTZ 1ST BAND PASS FIRST FUNCTION
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION68.0 MEGAHERTZ 2ND BAND PASS AND 72.0 MEGAHERTZ 2ND BAND PASS SECOND FUNCTION
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION68.0 MEGAHERTZ 3RD BAND PASS AND 72.0 MEGAHERTZ 3RD BAND PASS THIRD FUNCTION
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION68.0 MEGAHERTZ 4TH BAND PASS AND 72.0 MEGAHERTZ 4TH BAND PASS FOURTH FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION45.00 MEGAHERTZ 2ND BAND PASS AND 68.00 MEGAHERTZ 2ND BAND PASS AND 72.00 MEGAHERTZ 2ND BAND PASS AND 95.00 MEGAHERTZ 2ND BAND PASS SECOND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION45.00 MEGAHERTZ 3RD BAND PASS AND 68.00 MEGAHERTZ 3RD BAND PASS AND 72.00 MEGAHERTZ 3RD BAND PASS AND 95.00 MEGAHERTZ 3RD BAND PASS THIRD FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION45.00 MEGAHERTZ 4TH BAND PASS AND 68.00 MEGAHERTZ 4TH BAND PASS AND 72.00 MEGAHERTZ 4TH BAND PASS AND 95.00 MEGAHERTZ 4TH BAND PASS FOURTH FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION45.00 MEGAHERTZ 1ST BAND PASS AND 68.00 MEGAHERTZ 1ST BAND PASS AND 72.00 MEGAHERTZ 1ST BAND PASS AND 95.00 MEGAHERTZ 1ST BAND PASS FIRST FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE