5915-01-336-3696 FILTER,BAND PASS Index 5915-01-336-3698 FILTER,BAND PASS

National Stock Number:
5915-01-336-3697

Federal Supply Class:
5915

National Item Identification Number:
013363697

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
78E6N333902387NAVAL AIR WARFARE CENTER AIRCRAFT DIV
78E6N333928687NAVY, UNITED STATES DEPARTMENT OF THE SPAWAR DBA SPACE AND NAVAL WAFARE COMMAND
78E6N333950140K&L MICROWAVE LLC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION2.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY OUTSIDE DIAMETER0.250 INCHES NOMINAL
BODY MATERIALMETAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 30.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FEATURES PROVIDEDSHOCK RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION2.112 GIGAHERTZ BLANK AND 4.387 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
INPUT TERMINAL MANUFACTURER CODE50140
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 71.0 CELSIUS
OUTPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
OUTPUT TERMINAL MANUFACTURER CODE50140
OVERALL LENGTH3.000 INCHES MINIMUM AND 3.400 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION3.2495 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION2.112 GIGAHERTZ BLANK AND 4.387 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION900.00 MEGAHERTZ BLANK AND 2.112 GIGAHERTZ BLANK AND 4.387 GIGAHERTZ BLANK AND 5.20 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES