| AVERAGE POWER RATING PER FUNCTION | 2.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| BODY OUTSIDE DIAMETER | 0.250 INCHES NOMINAL |
| BODY MATERIAL | METAL |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM BLANK AND 30.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED |
| FEATURES PROVIDED | SHOCK RESISTANT |
| FREQUENCY BAND WIDTH PER FUNCTION | 3.93 GIGAHERTZ BLANK AND 8.07 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION |
| INCLOSURE TYPE | ENCASED |
| INPUT TERMINAL IDENTIFICATION | SMA-RECEPTACLE |
| INPUT TERMINAL MANUFACTURER CODE | 50140 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 2.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED |
| OPERATING TEMP RANGE | -55.0 TO 71.0 CELSIUS |
| OUTPUT TERMINAL IDENTIFICATION | SMA-RECEPTACLE |
| OUTPUT TERMINAL MANUFACTURER CODE | 50140 |
| OVERALL LENGTH | 2.750 INCHES MINIMUM AND 3.150 INCHES MAXIMUM |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED |
| REFERENCE FREQUENCY PER FUNCTION | 12.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 2.50 GIGAHERTZ BLANK AND 3.93 GIGAHERTZ BLANK AND 8.07 GIGAHERTZ BLANK AND 9.00 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| STYLE DESIGNATOR | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 2000.0 |
| VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | 3.93 GIGAHERTZ BLANK AND 8.07 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | 2.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |