4820-01-332-8450 VALVE,BLEEDER,HYDRAULIC SYSTEM Index 5915-01-332-8452 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-332-8451

Federal Supply Class:
5915

National Item Identification Number:
013328451

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
241-0782-01013499ROCKWELL COLLINS, INC.
30155465628CAES SYSTEMS LLC
31B10-1401.5/70-XP50140K&L MICROWAVE LLC


Techincal Specification:
BODY HEIGHT0.310 INCHES NOMINAL
BODY LENGTH0.750 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH0.440 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 40.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH0.630 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.318 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FEATURES PROVIDEDMOISTURE RESISTANT AND SHOCK RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION1.366 GIGAHERTZ BLANK AND 1.436 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH1.250 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.060 INCHES
OPERATING TEMP RANGE-55.0 TO 105.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION1.4015 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.051 GIGAHERTZ BLANK AND 1.366 GIGAHERTZ BLANK AND 1.436 GIGAHERTZ BLANK AND 1.751 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION1.38 GIGAHERTZ BLANK AND 1.42 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial