| BODY MATERIAL | METAL |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 1.0 MINIMUM BLANK AND 30.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 RECTANGULAR FLANGE INPUT FIRST FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 RECTANGULAR FLANGE OUTPUT SECOND FUNCTION |
| FREQUENCY BAND WIDTH PER FUNCTION | 7.25 GIGAHERTZ BLANK AND 7.75 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| INCLOSURE TYPE | ENCASED |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 0.1 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| OPERATING TEMP RANGE | +0.0 TO 75.0 CELSIUS |
| OVERALL LENGTH | 9.630 INCHES MINIMUM AND 9.670 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 8 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED |
| REFERENCE FREQUENCY PER FUNCTION | 7.5 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| SPECIAL FEATURES | NUCLEAR HARDNESS CRITICAL ITEM |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.170 INCHES NOMINAL |
| VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | 7.25 GIGAHERTZ BLANK AND 7.75 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.3 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 6.60 GIGAHERTZ BLANK AND 7.25 GIGAHERTZ BLANK AND 7.75 GIGAHERTZ BLANK AND 7.90 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |