5915-01-331-4072 FILTER,RADIO FREQUENCY INTERFERE Index 5930-01-331-4074 SWITCH,THERMOSTATIC

National Stock Number:
5915-01-331-4073

Federal Supply Class:
5915

National Item Identification Number:
013314073

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
5006-003613050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON
841786-106481NORTHROP GRUMMAN SYSTEMS CORPORATION
RF1274213619EMS DEVELOPMENT CORPORATION
841786-113973LITTON SYSTEMS INC. DIV NAVIGATION SYSTEMS DIVISION
A-575323939THE CAPTOR CORPORATION
CNA 2006-0566230PACIFIC AEROSPACE & ELECTRONICS, LLC
WFV357305245TE CONNECTIVITY CORPORATION


Techincal Specification:
AVERAGE LIFE RATING IN HOURS1000.0
BODY HEIGHT1.750 INCHES MINIMUM AND 1.770 INCHES MAXIMUM
BODY LENGTH5.230 INCHES MINIMUM AND 5.250 INCHES MAXIMUM
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN
BODY WIDTH1.750 INCHES MINIMUM AND 1.770 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.340 INCHES MINIMUM AND 1.360 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 THREADED STUD GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 THREADED STUD INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 THREADED STUD OUTPUT SECOND FUNCTION
FEATURES PROVIDEDFUNGUS RESISTANT AND SHOCK RESISTANT
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS1.5 AND 3.0 AND 78.0 AND 100.0
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION2.0 KILOHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION2.0 KILOHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION2.0 KILOHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
LOAD IMPEDANCE PER FUNCTION2.0 KILOHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING TEMP RANGE-54.0 TO 65.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION5.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION5.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION5.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION5.0 VOLTS AC 4TH RADIO INTERFERENCE FOURTH FUNCTION
OVERALL LENGTH6.590 INCHES MINIMUM AND 6.650 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE500.0 VOLTS AT SEA LEVEL
MAXIMUM VOLTAGE DROP PER FUNCTION50.0 MILLIVOLTS AC 4TH RADIO INTERFERENCE FOURTH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION50.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION50.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION50.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.164 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION2.0 KILOHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION2.0 KILOHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION2.0 KILOHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION2.0 KILOHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ5000.0 1ST RADIO INTERFERENCE FIRST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ5000.0 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ5000.0 3RD RADIO INTERFERENCE THIRD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ5000.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE FOURTH FUNCTION
SPECIAL FEATURESFOUR FILTERED FUNCTIONS
UNPACKAGED UNIT WEIGHT1.800 POUNDS NOMINAL
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 500.0
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial