3120-01-329-7112 BEARING,WASHER,THRUST Index 5915-01-329-7114 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-329-7113

Federal Supply Class:
5915

National Item Identification Number:
013297113

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
2IB32-200/TW5-P/P50140K&L MICROWAVE LLC
2IB32-200/XT5-P/P50140K&L MICROWAVE LLC
G452158-13B150RAYTHEON COMPANY
G452158-149956RAYTHEON COMPANY
G452158-154X10RAYTHEON COMPANY


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION1.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY HEIGHT0.380 INCHES NOMINAL
BODY LENGTH0.750 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH0.380 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 30.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH0.600 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.260 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION197.50 MEGAHERTZ BLANK AND 202.50 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT0.500 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 PIN(S) LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 25.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION200.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION195.00 MEGAHERTZ BLANK AND 197.50 MEGAHERTZ BLANK AND 202.50 MEGAHERTZ BLANK AND 205.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION197.5 MEGAHERTZ BLANK AND 202.5 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE