| BODY HEIGHT | 2.250 INCHES NOMINAL |
| BODY MATERIAL | METAL |
| BODY LENGTH | 6.110 INCHES MAXIMUM |
| BODY WIDTH | 4.500 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 4.000 INCHES NOMINAL |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD INPUT FIRST FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD OUTPUT SECOND FUNCTION |
| FEATURES PROVIDED | NUT |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OVERALL LENGTH | 7.490 INCHES MAXIMUM |
| MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 1.0 KILOVOLTS AT SEA LEVEL |
| MAXIMUM TEMP RISE | 35.0 CELSIUS |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.5 VOLTS AC 3RD RADIO INTERFERENCE AND 1.5 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.5 VOLTS AC 1ST RADIO INTERFERENCE AND 1.5 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.5 VOLTS AC 2ND RADIO INTERFERENCE AND 1.5 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED |
| NOMINAL THREAD SIZE | 0.190 INCHES |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE AND 400.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE AND 400.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE AND 400.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OPERATING TEMP RANGE | -55.0 TO 85.0 CELSIUS |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION |
| SPECIAL FEATURES | THREE UNFILTERED CONNECTORS |
| VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 500.0 |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| UNPACKAGED UNIT WEIGHT | 4.410 POUNDS NOMINAL |