5935-01-324-5845 CONNECTOR,RECEPTACLE,ELECTRICAL Index 5915-01-324-5847 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-324-5846

Federal Supply Class:
5915

National Item Identification Number:
013245846

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
4010-1486-1126401SOUTHWEST RESEARCH INSTITUTE
6IB14-30/X620-0/050140K&L MICROWAVE LLC


Techincal Specification:
AVERAGE LIFE RATING IN HOURS5300000.0
BODY HEIGHT0.400 INCHES NOMINAL
BODY LENGTH1.500 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH0.614 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS5.0 MINIMUM BLANK AND 30.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.414 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.300 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, PLUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, PLUG OUTPUT SECOND FUNCTION
FEATURES PROVIDEDMOISTURE RESISTANT AND SHOCK RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION30.00 MEGAHERTZ BLANK AND 620.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 50.0 CELSIUS
OVERALL LENGTH1.800 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION295.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
UNTHREADED MOUNTING HOLE DIAMETER0.102 INCHES MINIMUM AND 0.110 INCHES MAXIMUM
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION30.0 MEGAHERTZ BLANK AND 620.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION16.00 MEGAHERTZ BLANK AND 30.00 MEGAHERTZ BLANK AND 620.00 MEGAHERTZ BLANK AND 1.18 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES