4820-01-323-1184 VALVE,BALL Index 5915-01-323-1186 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-323-1185

Federal Supply Class:
5915

National Item Identification Number:
013231185

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
3JX5103C56289SPRAGUE ELECTRIC CO WORLD HQS


Techincal Specification:
BODY LENGTH1.820 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.320 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.125 INCHES NOMINAL
FEATURES PROVIDEDMOUNTING BRACKET
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 WIRE LEAD GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 WIRE LEAD INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 WIRE LEAD OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE240.0 VOLTS AT SEA LEVEL
MAXIMUM VOLTAGE DROP PER FUNCTION1.2 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.2 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OVERALL HEIGHT0.780 INCHES MAXIMUM
OVERALL LENGTH2.530 INCHES MAXIMUM
OVERALL WIDTH15.320 INCHES MAXIMUM
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES