5935-01-317-2488 CONNECTOR BODY,RECEPTACLE,ELECTR Index 5930-01-317-2490 SWITCH,FLOW

National Stock Number:
5915-01-317-2489

Federal Supply Class:
5915

National Item Identification Number:
013172489

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
28-10052-181205THE BOEING COMPANY
E7B51-300/80-XO/XC50140K&L MICROWAVE LLC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION5.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY LENGTH3.600 INCHES MINIMUM AND 5.000 INCHES MAXIMUM
BODY MATERIALALUMINUM
BODY SURFACE TREATMENTNICKEL
BODY WIDTH2.100 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.970 INCHES MINIMUM AND 3.030 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.365 INCHES MINIMUM AND 1.385 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, PLUG OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FEATURES PROVIDEDELLIPTICAL RESPONSE AND CORROSION RESISTANT AND FUNGUS RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION260.00 MEGAHERTZ BLANK AND 340.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATIONBACC64BS1
INPUT TERMINAL MANUFACTURER CODE81205
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OUTPUT TERMINAL IDENTIFICATIONBACC64BC1
OUTPUT TERMINAL MANUFACTURER CODE81205
OVERALL HEIGHT1.750 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION300.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESOUTPUT CONNECTOR ON A 36 IN. COAXIAL CABLE
SPECIFICATION/STANDARD DATA81205-28-10052 MANUFACTURERS SOURCE CONTROL
UNTHREADED MOUNTING HOLE DIAMETER0.280 INCHES MINIMUM AND 0.300 INCHES MAXIMUM
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION270.0 MEGAHERTZ BLANK AND 330.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.4 BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES