5995-01-315-5697 CABLE AND CONDUIT ASSEMBLY,ELECT Index 4240-01-315-5699 VALVE,OUTLET,PROTECTIVE ENTRANCE

National Stock Number:
5915-01-315-5698

Federal Supply Class:
5915

National Item Identification Number:
013155698

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
M15733-74-002181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-F-15733/7481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RF09710-19L13619EMS DEVELOPMENT CORPORATION
RF9710-19L13619EMS DEVELOPMENT CORPORATION


Techincal Specification:
BODY LENGTH4.310 INCHES MINIMUM AND 4.430 INCHES MAXIMUM
BODY OUTSIDE DIAMETER1.270 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 THREADED STUD INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 THREADED STUD OUTPUT SECOND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH5.390 INCHES MAXIMUM
MAXIMUM VOLTAGE DROP PER FUNCTION1.25 VOLTS AC BLANK AND 1.25 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
NOMINAL THREAD SIZE0.438 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC BLANK AND 600.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESFUNCTION: FILTER, RFI, FA 10047; REFERENCE DATA: TI 6850.83, FA 10266, 6A1FL1, PG 8-14
SPECIFICATION/STANDARD DATA81349-MIL-F-15733/74 GOVERNMENT SPECIFICATION
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
TEST DATA DOCUMENT81349-MIL-F-15733 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0