5930-01-301-6768 SWITCH,TOGGLE Index 5915-01-301-6770 FILTER,BAND PASS

National Stock Number:
5915-01-301-6769

Federal Supply Class:
5915

National Item Identification Number:
013016769

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
6011337-01112436BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
FBT/0.2-5G5/2G-7/50-28A/28A23042TRILITHIC, INC.


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION2.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY OUTSIDE DIAMETER0.230 INCHES MINIMUM AND 0.270 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS40.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION4.50 GIGAHERTZ BLANK AND 6.50 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONMIL-C-39012
INPUT TERMINAL MANUFACTURER CODE81349
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.73 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATIONMIL-C-39012
OUTPUT TERMINAL MANUFACTURER CODE81349
OVERALL LENGTH2.690 INCHES MINIMUM AND 2.810 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION5.5 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION4.5 GIGAHERTZ BLANK AND 7.5 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION3.80 GIGAHERTZ BLANK AND 4.50 GIGAHERTZ BLANK AND 6.50 GIGAHERTZ BLANK AND 7.20 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES