| BODY HEIGHT | 4.500 INCHES MAXIMUM |
| BODY LENGTH | 10.000 INCHES MAXIMUM |
| BODY MATERIAL | METAL |
| BODY SURFACE TREATMENT | TIN |
| BODY WIDTH | 6.000 INCHES MAXIMUM |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 4.500 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 8.500 INCHES NOMINAL |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 THREADED STUD GROUND THIRD FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD OUTPUT SECOND FUNCTION |
| FEATURES PROVIDED | SHOCK RESISTANT |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OVERALL HEIGHT | 7.156 INCHES NOMINAL |
| MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 2.5 KILOVOLTS AT SEA LEVEL |
| MAXIMUM TEMP RISE | 40.0 CELSIUS |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.2 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.2 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.2 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| NOMINAL THREAD SIZE | 0.250 INCHES |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 40.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 40.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 40.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OPERATING TEMP RANGE | +0.0 TO 85.0 CELSIUS |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 127.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 127.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 127.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION |
| VIBRATION RESISTANCE RANGE IN HERTZ | +5.0 TO 55.0 |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| UNPACKAGED UNIT WEIGHT | 25.000 POUNDS NOMINAL |