5915-01-295-8470 FILTER,RADIO FREQUENCY INTERFERE Index 5915-01-295-8472 FILTER,HIGH PASS

National Stock Number:
5915-01-295-8471

Federal Supply Class:
5915

National Item Identification Number:
012958471

Description:
FILTER,HIGH PASS

Detail:
AN ITEM DESIGNED TO PASS ALL FREQUENCIES ABOVE A SPECIFIED FREQUENCY. EXCLUDES A SINGLE INDUCTANCE, A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); REACTOR; CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).


Manufacturer Information:
6309867-153711NAVAL SEA SYSTEMS COMMAND
7439-400 HZ52339FREQUENCY DEVICES, INC.


Techincal Specification:
BODY HEIGHT1.000 INCHES NOMINAL
BODY LENGTH3.000 INCHES NOMINAL
BODY WIDTH2.000 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS51.56 MINIMUM BLANK AND 75.55 MINIMUM BLANK AND 3.0 MAXIMUM BLANK AND 1.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.000 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION400.00 HERTZ BLANK AND 4.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.8 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION150.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT1.200 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.138 INCHES
OPERATING TEMP RANGE+0.0 TO 70.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION150.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESACTIVE HIGHPASS FILTER; TWO 15VDC SUPPLY (+V,-V) AND ONE OFFSET VOLTAGE ADJUSTMENT (OS1) TERMINALS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION2.2 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION40.00 HERTZ BLANK AND 200.00 HERTZ BLANK AND 400.00 HERTZ BLANK AND 4.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE