5935-01-293-8353 CONNECTOR BODY,PLUG,ELECTRICAL Index 5930-01-293-8355 SWITCH,PRESSURE

National Stock Number:
5915-01-293-8354

Federal Supply Class:
5915

National Item Identification Number:
012938354

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
425319-100752L3HARRIS TECHNOLOGIES, INC.
LP6B250-3500/X1170-050140K&L MICROWAVE LLC


Techincal Specification:
BODY OUTSIDE DIAMETER0.230 INCHES MINIMUM AND 0.270 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS40.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION2.91 GIGAHERTZ BLANK AND 4.08 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
INPUT TERMINAL MANUFACTURER CODE50140
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
OUTPUT TERMINAL MANUFACTURER CODE50140
OVERALL LENGTH2.440 INCHES MINIMUM AND 2.560 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION3.495 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: OZ1.000
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.20 GIGAHERTZ BLANK AND 2.91 GIGAHERTZ BLANK AND 4.08 GIGAHERTZ BLANK AND 5.80 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION2.91 GIGAHERTZ BLANK AND 4.08 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES