5915-01-280-0805 FILTER,BAND PASS Index 5915-01-280-0807 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-280-0806

Federal Supply Class:
5915

National Item Identification Number:
012800806

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
10M10-123876301THE BOEING COMPANY
3B250-4300-130-0P-050140K&L MICROWAVE LLC


Techincal Specification:
BODY LENGTH0.500 INCHES NOMINAL
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER0.250 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS25.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK AND 26.0 MINIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, PLUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION4.235 GIGAHERTZ BLANK AND 4.365 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONSMA-PLUG
INPUT TERMINAL MANUFACTURER CODE50140
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
OUTPUT TERMINAL MANUFACTURER CODE50140
OVERALL LENGTH1.830 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION4.3 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 2000.0
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION4.235 GIGAHERTZ BLANK AND 4.365 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION4.04 GIGAHERTZ BLANK AND 4.235 GIGAHERTZ BLANK AND 4.365 GIGAHERTZ BLANK AND 4.56 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES