5915-01-256-9601 NETWORK,CIRCUIT PROTECTION Index 5915-01-256-9603 NETWORK,CIRCUIT PROTECTION

National Stock Number:
5915-01-256-9602

Federal Supply Class:
5915

National Item Identification Number:
012569602

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
AM1237722558COAST/ADVANCED CHIP MAGNETICS, INC.
SCD85297098571TELEDYNE CONTROLS, LLC


Techincal Specification:
BODY HEIGHT0.325 INCHES MAXIMUM
BODY LENGTH2.000 INCHES MAXIMUM
BODY MATERIALPLASTIC
BODY WIDTH1.700 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 30.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH0.900 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN OUTPUT SECOND FUNCTION
FEATURES PROVIDEDACTIVE
FREQUENCY BAND WIDTH PER FUNCTION1.00 HERTZ BLANK AND 31.50 HERTZ BLANK FIRST FUNCTION
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 1ST LOW PASS FIRST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 2ND LOW PASS SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION31.5 OHMS 1ST LOW PASS FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION31.5 OHMS 2ND LOW PASS SECOND FUNCTION
OUTPUT VOLTAGE RATING5.0 DC VOLTS NOMINAL
OVERALL HEIGHT0.825 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY6 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION31.5 OHMS 1ST LOW PASS FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION31.5 OHMS 2ND LOW PASS SECOND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND LOW PASS SECOND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST LOW PASS FIRST FUNCTION
REFERENCE FREQUENCY PER FUNCTION31.5 HERTZ 1ST LOW PASS FIRST FUNCTION
REFERENCE FREQUENCY PER FUNCTION31.5 HERTZ 2ND LOW PASS SECOND FUNCTION
SPECIAL FEATURESTWO FILTERED FUNCTIONS
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.00 HERTZ BLANK AND 31.50 HERTZ BLANK AND 32.30 HERTZ BLANK AND 32.75 HERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE