5915-01-252-3212 FILTER,BAND PASS Index 5915-01-252-3214 FILTER,BAND PASS

National Stock Number:
5915-01-252-3213

Federal Supply Class:
5915

National Item Identification Number:
012523213

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
5IB10-1392/X24-P/P50140K&L MICROWAVE LLC
BPF-L-132-200-0663455216CONCISE ENGINEERING AND MFG
G267059-93B150RAYTHEON COMPANY
G267059-949956RAYTHEON COMPANY
G267059-954X10RAYTHEON COMPANY


Techincal Specification:
AVERAGE LIFE RATING IN HOURS4000.0
BODY HEIGHT0.220 INCHES NOMINAL
BODY LENGTH1.100 INCHES NOMINAL
BODY MATERIALMETAL
BODY SURFACE TREATMENTSILVER
BODY WIDTH0.400 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS33.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.300 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.000 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.3915 GIGAHERTZ BLANK AND 1.3925 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS4.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-54.0 TO 85.0 CELSIUS
OVERALL LENGTH1.460 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRECIOUS MATERIAL AND LOCATIONBODY SURFACES SILVER
PRECIOUS MATERIALSILVER
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION1.392 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
UNTHREADED MOUNTING HOLE DIAMETER0.080 INCHES MAXIMUM
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 500.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.328 GIGAHERTZ BLANK AND 1.3915 GIGAHERTZ BLANK AND 1.3925 GIGAHERTZ BLANK AND 1.456 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial