5915-01-245-4687 FILTER,BAND PASS Index 5930-01-245-4689 SWITCH,ROTARY

National Stock Number:
5915-01-245-4688

Federal Supply Class:
5915

National Item Identification Number:
012454688

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
77C714729G00303538LOCKHEED MARTIN CORPORATION
77C714729G303538LOCKHEED MARTIN CORPORATION
77C721190P00103538LOCKHEED MARTIN CORPORATION


Techincal Specification:
BODY HEIGHT4.500 INCHES NOMINAL
BODY LENGTH2.250 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH2.125 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS45.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.700 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.600 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION3.86 KILOHERTZ BLANK AND 3.96 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION2.6 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+15.0 TO 45.0 CELSIUS
OVERALL HEIGHT5.000 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.190 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION1.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION3.91 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION3.71 KILOHERTZ BLANK AND 3.86 KILOHERTZ BLANK AND 3.96 KILOHERTZ BLANK AND 4.18 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE