| BODY HEIGHT | 3.500 INCHES NOMINAL |
| BODY LENGTH | 5.120 INCHES NOMINAL |
| BODY MATERIAL | METAL |
| BODY WIDTH | 2.000 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.125 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.500 INCHES NOMINAL |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 5 SCREW INPUT FIRST FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 5 SCREW OUTPUT SECOND FUNCTION |
| INCLOSURE TYPE | ENCASED |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING TEMP RANGE | -55.0 TO 85.0 CELSIUS |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| OVERALL HEIGHT | 4.000 INCHES NOMINAL |
| MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 230.0 VOLTS AT SEA LEVEL |
| MAXIMUM TEMP RISE | 25.0 CELSIUS |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| NOMINAL THREAD SIZE | 0.138 INCHES |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| SPECIAL FEATURES | FIVE FILTERED FUNCTIONS |
| VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 500.0 |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |