3120-01-228-8709 BUSHING,SLEEVE Index 5930-01-228-8711 SWITCH,PRESSURE

National Stock Number:
5915-01-228-8710

Federal Supply Class:
5915

National Item Identification Number:
012288710

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
731012-105869RAYTHEON COMPANY
NF2126405245TE CONNECTIVITY CORPORATION
NF2129205245TE CONNECTIVITY CORPORATION


Techincal Specification:
DISTANCE BETWEEN MOUNTING SURFACE AND LOWER END3.750 INCHES NOMINAL
AVERAGE LIFE RATING IN HOURS250.0
BODY HEIGHT6.000 INCHES NOMINAL
BODY LENGTH16.000 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH4.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH5.250 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH17.250 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY6 PIN OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONMS3400D22-23P
INPUT TERMINAL MANUFACTURER CODE96906
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 5TH RADIO INTERFERENCE FIFTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 6TH RADIO INTERFERENCE SIXTH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 5TH RADIO INTERFERENCE FIFTH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 6TH RADIO INTERFERENCE SIXTH FUNCTION
OVERALL HEIGHT7.370 INCHES NOMINAL
OVERALL LENGTH18.000 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE600.0 VOLTS AT SEA LEVEL
MAXIMUM TEMP RISE60.0 CELSIUS
MOUNTING FACILITY TYPE AND QUANTITY24 UNTHREADED HOLE(S) ALL FUNCTIONS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ63.0 1ST RADIO INTERFERENCE FIRST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ63.0 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ63.0 3RD RADIO INTERFERENCE THIRD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ63.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ63.0 5TH RADIO INTERFERENCE FIFTH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ63.0 6TH RADIO INTERFERENCE SIXTH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE-RESISTANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE-RESISTANCE 3RD RADIO INTERFERENCE THIRD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE-RESISTANCE 4TH RADIO INTERFERENCE FOURTH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE-RESISTANCE 5TH RADIO INTERFERENCE FIFTH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE-RESISTANCE 6TH RADIO INTERFERENCE SIXTH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE-RESISTANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
UNPACKAGED UNIT WEIGHT25.000 POUNDS NOMINAL
UNTHREADED MOUNTING HOLE DIAMETER0.256 INCHES MINIMUM AND 0.263 INCHES MAXIMUM
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial