5935-01-206-9428 CONNECTOR,RECEPTACLE,ELECTRICAL Index 5915-01-206-9430 FILTER,BAND PASS

National Stock Number:
5915-01-206-9429

Federal Supply Class:
5915

National Item Identification Number:
012069429

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
19B6500136MICROSEMI CORP. - HIGH PERFORMANCE TIMING
B402827356996DEPARTMENT OF THE ARMY HQ UNITED STATES ARMY COMMUNICATIONS RESEARCH AND DEVELOPMENT COMMAND
B402827380045L3HARRIS CINCINNATI ELECTRONICS CORPORATION


Techincal Specification:
BODY HEIGHT0.390 INCHES MAXIMUM
BODY LENGTH1.300 INCHES NOMINAL
BODY WIDTH1.000 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 PIN GROUND THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION69.375 MEGAHERTZ BLANK AND 69.425 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS7.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-32.0 TO 85.0 CELSIUS
OVERALL LENGTH1.516 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY6 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION69.4 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: GM25.0
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 500.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION69.350 MEGAHERTZ BLANK AND 69.375 MEGAHERTZ BLANK AND 69.425 MEGAHERTZ BLANK AND 69.450 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial