5915-01-193-8386 FILTER,RADIO FREQUENCY INTERFERE Index 5930-01-193-8388 SWITCH,ROTARY

National Stock Number:
5915-01-193-8387

Federal Supply Class:
5915

National Item Identification Number:
011938387

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
16177621877NORTHROP GRUMMAN SYSTEMS CORPORATION
RF10242B13619EMS DEVELOPMENT CORPORATION


Techincal Specification:
AVERAGE LIFE RATING IN HOURS5000.0
BODY HEIGHT2.000 INCHES NOMINAL
BODY LENGTH7.995 INCHES NOMINAL
BODY WIDTH3.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 THREADED STUD INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 THREADED STUD OUTPUT SECOND FUNCTION
FEATURES PROVIDEDSHOCK RESISTANT
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
OVERALL LENGTH9.495 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE1.45 KILOVOLTS AT SEA LEVEL
MAXIMUM TEMP RISE10.0 CELSIUS
MAXIMUM VOLTAGE DROP PER FUNCTION2.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY2 SLOT SECOND FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE(S) THIRD FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) FIRST FUNCTION
MOUNTING SLOT WIDTH0.250 INCHES NOMINAL
NOMINAL THREAD SIZE0.164 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING TEMP RANGE-0.0 TO 70.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION484.0 VOLTS AC 1ST RADIO INTERFERENCE AND 1.13 KILOVOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION484.0 VOLTS AC 2ND RADIO INTERFERENCE AND 1.13 KILOVOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 3RD RADIO INTERFERENCE THIRD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 33.0
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNPACKAGED UNIT WEIGHT5.000 POUNDS NOMINAL