4820-01-189-3174 VALVE,BALL Index 5915-01-189-3176 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-189-3175

Federal Supply Class:
5915

National Item Identification Number:
011893175

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
137FP38901456MICROWAVE DEVELOPMENT LABORATORIES, INC.
5541945-153711NAVAL SEA SYSTEMS COMMAND


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION1.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY HEIGHT0.750 INCHES NOMINAL0.750 INCHES NOMINAL
BODY LENGTH7.250 INCHES NOMINAL7.250 INCHES NOMINAL
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN
BODY WIDTH4.030 INCHES MAXIMUM4.030 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS55.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 RECTANGULAR FLANGE INPUT FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION5.45 GIGAHERTZ BLANK AND 5.825 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.3 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-0.0 TO 65.0 CELSIUS-0.0 TO 65.0 CELSIUS
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION5.6375 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: LB3.000
VIBRATION RESISTANCE RANGE IN HERTZ+4.0 TO 25.0+4.0 TO 25.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION5.45 GIGAHERTZ BLANK AND 5.825 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.2 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION6.11 GIGAHERTZ BLANK AND 5.45 GIGAHERTZ BLANK AND 5.825 GIGAHERTZ BLANK AND 7.147 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED


Click here to Register for Free 30-day Trial