5915-01-187-4929 FILTER,BAND PASS Index 5915-01-187-4931 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-187-4930

Federal Supply Class:
5915

National Item Identification Number:
011874930

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
10446001-0127963GENERAL DYNAMICS INFORMATION SYSTEMS INC. DBA GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS
1044601-013CYA2GENERAL DYNAMICS MISSION SYSTEMS, INC.
526263415090RAYTHEON COMPANY
526263453711NAVAL SEA SYSTEMS COMMAND
5915PL09579959009HINSPEKTORAT WSPARCIA SIL ZBROJNYCH


Techincal Specification:
BODY HEIGHT6.000 INCHES NOMINAL
BODY LENGTH9.000 INCHES NOMINAL
BODY WIDTH1.170 INCHES NOMINAL
INCLOSURE TYPEENCASED
MAXIMUM VOLTAGE DROP PER FUNCTION27.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION33.0 MILLIVOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION40.0 MILLIVOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION7.0 MILLIVOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS15.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.8 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION12.0 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION15.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION28.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION5.05 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE