| BODY LENGTH | 5.500 INCHES MAXIMUM |
| BODY WIDTH | 1.250 INCHES MAXIMUM |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.875 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.875 INCHES NOMINAL |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 TAB, SOLDER LUG INPUT-OUTPUT LOCATION NOT OTHERWISE SPECIFIED |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| LOAD IMPEDANCE PER FUNCTION | 0.95 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 0.95 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 0.95 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OVERALL HEIGHT | 4.560 INCHES MAXIMUM |
| OVERALL WIDTH | 3.500 INCHES MAXIMUM |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 2.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 2.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 2.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED |
| NOMINAL THREAD SIZE | 0.380 INCHES |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 8.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 8.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 8.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 360.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| SPECIAL FEATURES | NUCLEAR HARDENED CRITICAL DESIGN |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ADJACENT SURFACES |