5330-01-168-3886 RETAINER,PACKING Index 5935-01-168-3888 CONNECTOR,RECEPTACLE,ELECTRICAL

National Stock Number:
5915-01-168-3887

Federal Supply Class:
5915

National Item Identification Number:
011683887

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
68-157344-128815NORTHROP GRUMMAN SYSTEMS CORPORATION


Techincal Specification:
BODY HEIGHT2.080 INCHES MINIMUM AND 2.120 INCHES MAXIMUM
BODY LENGTH1.380 INCHES MAXIMUM
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN
BODY WIDTH2.080 INCHES MINIMUM AND 2.120 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.930 INCHES MINIMUM AND 1.950 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY8 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY8 TURRET GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONMS3470L16-8P
INPUT TERMINAL MANUFACTURER CODE96906
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 5TH RADIO INTERFERENCE FIFTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 6TH RADIO INTERFERENCE SIXTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING TEMP RANGE-55.0 TO 55.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS DC 5TH RADIO INTERFERENCE FIFTH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS DC 6TH RADIO INTERFERENCE SIXTH FUNCTION
OVERALL HEIGHT2.430 INCHES MAXIMUM
OVERALL LENGTH1.942 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE125.0 VOLTS AT SEA LEVEL
MAXIMUM TEMP RISE20.0 CELSIUS
MAXIMUM VOLTAGE DROP PER FUNCTION0.1 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION0.1 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION0.1 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION0.1 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION0.1 VOLTS DC 5TH RADIO INTERFERENCE FIFTH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION0.1 VOLTS DC 6TH RADIO INTERFERENCE SIXTH FUNCTION
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE FIFTH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE SIXTH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE FOURTH FUNCTION
SPECIAL FEATURESEIGHT FILTERED FUNCTIONS
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 500.0
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES