4810-01-164-2475 VALVE,SOLENOID Index 5915-01-164-2478 FILTER,BAND PASS

National Stock Number:
5915-01-164-2477

Federal Supply Class:
5915

National Item Identification Number:
011642477

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
074949-53303947MICRO NETWORKS CORPORATION
85118458068QORVO FLORIDA, INC. DBA QORVO US
951292-63B150RAYTHEON COMPANY
951292-649956RAYTHEON COMPANY
951292-654X10RAYTHEON COMPANY


Techincal Specification:
BODY HEIGHT0.200 INCHES MAXIMUM
BODY LENGTH1.368 INCHES MINIMUM AND 1.372 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH0.793 INCHES MINIMUM AND 0.797 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS35.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 PIN GROUND THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION70.398 MEGAHERTZ BLANK AND 71.298 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS34.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT0.375 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY8 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-18.0 TO 63.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION70.848 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESTWO SIGNAL RETURN TERMINALS; UNPACKAGED UNIT WEIGHT: OZ2.000
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 200.0
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION70.398 MEGAHERTZ BLANK AND 71.298 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION69.498 MEGAHERTZ BLANK AND 70.398 MEGAHERTZ BLANK AND 71.298 MEGAHERTZ BLANK AND 72.198 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
TEST DATA DOCUMENT49956-951292 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)


Click here to Register for Free 30-day Trial