5935-01-163-2550 CONNECTOR,RECEPTACLE,ELECTRICAL Index 5935-01-163-2552 CONNECTOR,RECEPTACLE,ELECTRICAL

National Stock Number:
5915-01-163-2551

Federal Supply Class:
5915

National Item Identification Number:
011632551

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
10135216A486GNIMIKKEISTOKESKUS NCB FINLAND
144A9617P789954BAE SYSTEMS CONTROLS INC.
KJJ105045-000271468ITT CANNON LLC
21-489015-20077820AMPHENOL CORP


Techincal Specification:
BODY MATERIALALUMINUM
BODY SURFACE TREATMENTCADMIUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.969 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH0.969 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY37 FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT LOCATION NOT OTHERWISE SPECIFIED
FEATURES PROVIDEDMOISTURE RESISTANT AND SHOCK RESISTANT
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.1 AND 1.0 AND 10.0 AND 100.0 AND 500.0 AND 1000.0
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS2.0 AND 10.0 AND 40.0 AND 75.0 AND 90.0
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATIONMIL-C-38999
INPUT TERMINAL MANUFACTURER CODE71468
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 6TH RADIO INTERFERENCE SIXTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 5TH RADIO INTERFERENCE FIFTH FUNCTION
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC 1ST RADIO INTERFERENCE AND 200.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC 3RD RADIO INTERFERENCE AND 200.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC 2ND RADIO INTERFERENCE AND 200.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC 5TH RADIO INTERFERENCE AND 200.0 VOLTS DC 5TH RADIO INTERFERENCE FIFTH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC 6TH RADIO INTERFERENCE AND 200.0 VOLTS DC 6TH RADIO INTERFERENCE SIXTH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION120.0 VOLTS AC 4TH RADIO INTERFERENCE AND 200.0 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION
OUTPUT TERMINAL IDENTIFICATIONMIL-C-38999
OUTPUT TERMINAL MANUFACTURER CODE71468
OVERALL HEIGHT1.219 INCHES NOMINAL
OVERALL LENGTH2.012 INCHES NOMINAL
OVERALL WIDTH1.219 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE300.0 VOLTS AT SEA LEVEL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE300.0 VOLTS AT SEA LEVEL
MAXIMUM TEMP RISE25.0 CELSIUS
MAXIMUM VOLTAGE DROP PER FUNCTION1.2 VOLTS AC 3RD RADIO INTERFERENCE AND 2.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.2 VOLTS AC 1ST RADIO INTERFERENCE AND 2.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.2 VOLTS AC 2ND RADIO INTERFERENCE AND 2.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.2 VOLTS AC 5TH RADIO INTERFERENCE AND 2.0 VOLTS DC 5TH RADIO INTERFERENCE FIFTH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.2 VOLTS AC 6TH RADIO INTERFERENCE AND 2.0 VOLTS DC 6TH RADIO INTERFERENCE SIXTH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.2 VOLTS AC 4TH RADIO INTERFERENCE AND 2.0 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE THIRD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 5TH RADIO INTERFERENCE FIFTH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 6TH RADIO INTERFERENCE SIXTH FUNCTION
PRECIOUS MATERIAL AND LOCATIONCONTACT SURFACES GOLD
PRECIOUS MATERIALGOLD
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE FIFTH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE SIXTH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE FOURTH FUNCTION
SPECIAL FEATURESTHIRTY-THREE FILTERED FUNCTIONS; FOUR GROUNDED CONTACTS
UNTHREADED MOUNTING HOLE DIAMETER0.126 INCHES MINIMUM AND 0.132 INCHES MAXIMUM
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 500.0
STYLE DESIGNATORFILTER CONNECTOR


Click here to Register for Free 30-day Trial