5930-01-158-8883 SWITCH,PRESSURE Index 5805-01-158-8885 TELEPHONE SET

National Stock Number:
5915-01-158-8884

Federal Supply Class:
5915

National Item Identification Number:
011588884

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
074949-53203947MICRO NETWORKS CORPORATION
85118558068QORVO FLORIDA, INC. DBA QORVO US
951292-532854NORTH AMERICAN TRANSFORMER INC
951292-53B150RAYTHEON COMPANY
951292-549956RAYTHEON COMPANY
951292-554X10RAYTHEON COMPANY
951292-558068QORVO FLORIDA, INC. DBA QORVO US
951292-573293STELLANT SYSTEMS INC


Techincal Specification:
AVERAGE LIFE RATING IN HOURS500000.0
BODY HEIGHT0.200 INCHES MAXIMUM
BODY LENGTH1.372 INCHES MAXIMUM
BODY WIDTH0.797 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS20.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 PIN GROUND THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION68.32 MEGAHERTZ BLANK AND 69.92 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS34.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-18.0 TO 63.0 CELSIUS
OVERALL HEIGHT0.375 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY8 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION69.12 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESTWO SIGNAL RETURN PIN TERMINALS; UNPACKAGED UNIT WEIGHT: OZ2.000
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 500.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION68.32 MEGAHERTZ BLANK AND 69.92 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION67.77 MEGAHERTZ BLANK AND 68.32 MEGAHERTZ BLANK AND 69.92 MEGAHERTZ BLANK AND 70.47 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE