5935-01-158-3757 CONNECTOR BODY,RECEPTACLE,ELECTR Index 5915-01-158-3759 FILTER,BAND PASS

National Stock Number:
5915-01-158-3758

Federal Supply Class:
5915

National Item Identification Number:
011583758

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
10B6357996FILTER RESEARCH CORPORATION
SM-A-838216-308715CEN ELECTRONICS A DIV OF CHLORIDE POWER ELECTRONICS INC
SM-A-838216-354832AEROFLEX LABORATORIES INC COMSTRON DIV
SM-A-838216-357996FILTER RESEARCH CORPORATION
SM-A-838216-380063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY HEIGHT0.580 INCHES MAXIMUM
BODY LENGTH3.035 INCHES MAXIMUM
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN
BODY WIDTH1.875 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 1ST BAND PASS AND 30.0 MAXIMUM 1ST BAND PASS FIRST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 2ND BAND PASS AND 30.0 MAXIMUM 2ND BAND PASS SECOND FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 3RD BAND PASS AND 30.0 MAXIMUM 3RD BAND PASS THIRD FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 4TH BAND PASS AND 30.0 MAXIMUM 4TH BAND PASS FOURTH FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 5TH BAND PASS AND 30.0 MAXIMUM 5TH BAND PASS FIFTH FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY5 PIN OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION10.944 KILOHERTZ 1ST BAND PASS AND 11.36 KILOHERTZ 1ST BAND PASS FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION12.08 KILOHERTZ 2ND BAND PASS AND 12.56 KILOHERTZ 2ND BAND PASS SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION13.36 KILOHERTZ 3RD BAND PASS AND 13.904 KILOHERTZ 3RD BAND PASS THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION14.752 KILOHERTZ 4TH BAND PASS AND 15.344 KILOHERTZ 4TH BAND PASS FOURTH FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION8.928 KILOHERTZ 5TH BAND PASS AND 9.312 KILOHERTZ 5TH BAND PASS FIFTH FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 1ST BAND PASS FIRST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 3RD BAND PASS THIRD FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 2ND BAND PASS SECOND FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 5TH BAND PASS FIFTH FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 4TH BAND PASS FOURTH FUNCTION
LOAD IMPEDANCE PER FUNCTION100.0 KILOHMS 3RD BAND PASS THIRD FUNCTION
LOAD IMPEDANCE PER FUNCTION100.0 KILOHMS 4TH BAND PASS FOURTH FUNCTION
LOAD IMPEDANCE PER FUNCTION100.0 KILOHMS 5TH BAND PASS FIFTH FUNCTION
LOAD IMPEDANCE PER FUNCTION100.0 KILOHMS 1ST BAND PASS FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION100.0 KILOHMS 2ND BAND PASS SECOND FUNCTION
OVERALL HEIGHT0.750 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY12 PIN(S) LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-29.0 TO 85.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 2ND BAND PASS SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 3RD BAND PASS THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 4TH BAND PASS FOURTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 5TH BAND PASS FIFTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS 1ST BAND PASS FIRST FUNCTION
REFERENCE FREQUENCY PER FUNCTION11.152 KILOHERTZ 1ST BAND PASS FIRST FUNCTION
REFERENCE FREQUENCY PER FUNCTION12.32 KILOHERTZ 2ND BAND PASS SECOND FUNCTION
REFERENCE FREQUENCY PER FUNCTION13.632 KILOHERTZ 3RD BAND PASS THIRD FUNCTION
REFERENCE FREQUENCY PER FUNCTION15.056 KILOHERTZ 4TH BAND PASS FOURTH FUNCTION
REFERENCE FREQUENCY PER FUNCTION9.12 KILOHERTZ 5TH BAND PASS FIFTH FUNCTION
SPECIAL FEATURESFIVE FILTERED FUNCTIONS; UNPACKAGED UNIT WEIGHT: OZ6.000
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION11.952 KILOHERTZ 2ND BAND PASS AND 12.08 KILOHERTZ 2ND BAND PASS AND 12.56 KILOHERTZ 2ND BAND PASS AND 12.704 KILOHERTZ 2ND BAND PASS SECOND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION13.216 KILOHERTZ 3RD BAND PASS AND 13.36 KILOHERTZ 3RD BAND PASS AND 13.904 KILOHERTZ 3RD BAND PASS AND 14.048 KILOHERTZ 3RD BAND PASS THIRD FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION14.608 KILOHERTZ 4TH BAND PASS AND 14.752 KILOHERTZ 4TH BAND PASS AND 15.344 KILOHERTZ 4TH BAND PASS AND 15.52 KILOHERTZ 4TH BAND PASS FOURTH FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION10.816 KILOHERTZ 1ST BAND PASS AND 10.944 KILOHERTZ 1ST BAND PASS AND 11.36 KILOHERTZ 1ST BAND PASS AND 11.488 KILOHERTZ 1ST BAND PASS FIRST FUNCTION
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION8.816 KILOHERTZ 5TH BAND PASS AND 8.928 KILOHERTZ 5TH BAND PASS AND 9.312 KILOHERTZ 5TH BAND PASS AND 9.424 KILOHERTZ 5TH BAND PASS FIFTH FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE